Diagnostics and Modeling of Gas Puff Target Laser Plasma Radiation Source

Š. Vondrová, M. Vrbová, D. Pánek, P. Brůža, P. Vrba, P. Wachulak, F. Krejčí, J. Jakůbek

Abstrakt

Here we present a study of XUV emission characteristics of nitrogen plasma induced by infrared laser pulse (800 mJ / 7 ns) focused into a gas puff target. Spatial distribution of nitrogen density was determined by EUV radiography at the wavelength 13.5 nm. We used Gaussian function to approximate the cross-section of the gas puff target in the direction perpendicular to the axis of the nozzle. The value of target mass density was estimated to be 3.7·10-4 g/cm3 at the distance z = 0.5mm from the nozzle and 4.9·10-4 g/cm3 at z =
0.25 mm from the nozzle. The resulting density profile at the focal region and measured time dependences of laser power were introduced as input data to 2D RMHD (Radiation-Magneto-Hydro-Dynamic) code Z* (EPPRA s.a.s, France). Spatial developments of nitrogen plasma quantities were modeled. The evaluated electron temperature at the center of gas puff target exceeded the value Te ~ 34 eV. The related peak value of emitted energy density, in the wavelength region 2.8766 - 2.8867 nm approached the value Qeuv ~ 0.3 J/cm3. The evaluated spatial distributions of emitted energy were compared with the experimental data obtained with a compact laser-based XUV source (Laser Laboratory Göttingen e.V., Germany).

Klíčová slova