Publikace

35 publikací
Vymazat
Název Autoři Druh výsledku Informace o publikaci Rok Citace
Multi bin energy-sensitive micro-CT using large area photon-counting detectors Timepix J. Dudák, J. Žemlička Článek v časopise Journal of Instrumentation. 2022, 17(-), ISSN 1748-0221. 2022 1
Applicability of large-area single-photon counting detectors Timepix for high-resolution and high-contrast X-ray imaging of biological samples J. Dudák, J. Žemlička, J. Mrzílková, P. Zach, K. Holcová Článek v časopise IEEE Transactions on Nuclear Science. 2022, 69(4), 753-760. ISSN 1558-1578. 2022 7
Application of 2 x 5 MPX3 camera with monolithic sensor for phase contrast imaging and computed tomography D. Vavrik, J. Dudák, X. Kumpova, J. Žemlička Článek v časopise Journal of Instrumentation. 2022, 17(3), ISSN 1748-0221. 2022 0
Method of phase gradient radiography and arrangement of an imaging system for application of the method F. Krejčí, J. Jakůbek Patent European Patent Office. Patent EP2978377. 2021-05-05. 2021 —
Evaluation of scan strategies for small animal in vivo micro-CT J. Dudák, D. Ekendahl, L. Judas, J. Mrzilkova, P. Rubovič, J. Žemlička Článek v časopise Journal of Instrumentation. 2020, 15(2), ISSN 1748-0221. 2020 0
Study of the contrast resolution of Timepix detector with a semi-insulating GaAs sensor B. Zatko, A. Sagatova, Z. Zaprazny, P. Bohacek, M. Sekáčová, E. Kováčová, J. Žemlička, J. Jakůbek, D. Korytár, N. Gál, V. Nečas Článek v časopise Journal of Instrumentation. 2020, 15(4), ISSN 1748-0221. 2020 3
Single absorption grating based X-ray phase contrast CT using Timepix detector J. Žemlička, J. Dudák, D. Kubanda, F. Krejčí Článek v časopise Journal of Instrumentation. 2019, 14 ISSN 1748-0221. 2019 3
Ethanol fixation method for heart and lung imaging in micro-CT M. Patzelt, J. Mrzilkova, J. Dudák, F. Krejčí, J. Žemlička, J. Karch, V. Musil, J. Rosina, P. Zach Článek v časopise Japanese journal of radiology. 2019, 37(6), 500-510. ISSN 1867-1071. 2019 22
Multimodal PSSMA-Functionalized GdF3 : Eu3+(Tb3+) Nanoparticles for Luminescence Imaging, MRI, and X-Ray Computed Tomography O. Shapoval, O. Kaman, J. Hromadkova, D. Vavřík Článek v časopise ChemPlusChem. 2019, 84(8), 1135-1139. ISSN 2192-6506. 2019 10
Experimentální systém pro fázově citlivou radiografii J. Žemlička, F. Krejčí, J. Dudák, J. Karch Užitný vzor Czechia. Utility Model CZ 31511. 2018-02-20. 2018 —
Table-top phase-contrast imaging employing photon-counting detectors towards mammographic applications K. Palma, M. Pichotka, S. Hasn, C. Granja Článek v časopise Journal of Instrumentation. 2017, 12(2), ISSN 1748-0221. 2017 2
Software pro řízení radiografických systémů - GUI pro fázový a dark-field kontrast J. Žemlička Software [Software (for RIV)] 2017. 2017 —
High-contrast X-ray micro-radiography and micro-CT of ex-vivo soft tissue murine organs utilizing ethanol fixation and large area photon-counting detector J. Dudák, J. Žemlička, J. Karch, M. Patzelt, J. Mrzílková, P. Zach, Z. Heřmanová, J. Kvaček, F. Krejčí Článek v časopise Scientific Reports. 2016, 6 ISSN 2045-2322. 2016 51
Experimentally enhanced model-based deconvolution of propagation-based phase-contrast data M. Pichotka, K. Palma Alejandro, S. Hasn, J. Jakůbek, D. Vavřík Článek v časopise Journal of Instrumentation. 2016, 2016(12), ISSN 1748-0221. 2016 1
X-ray micro-CT scanner for small animal imaging based on Timepix detector technology J. Dudák, J. Žemlička, F. Krejčí, Š. Polanský, J. Jakůbek, JM Mrzílková, MP Patzelt, JT Trnka Článek v časopise Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment. 2015, 773 81-86. ISSN 0168-9002. 2015 24
Visualization of delamination in composite materials utilizing advanced X-ray imaging techniques D. Vavřík, J. Jakůbek, I. Jandejsek, F. Krejčí, IK Kumpová, J. Žemlička Článek v časopise Journal of Instrumentation. 2015, 2015(10), 1-8. ISSN 1748-0221. 2015 16
Neutron and high-contrast X-ray micro-radiography as complementary tools for monitoring organosilicon consolidants in natural building stones MS Slavíková, F. Krejčí, PK Kotlík, J. Jakůbek, IT Tomandl, J. Vacík Článek v časopise Nuclear Instruments and Methods in Physics Research, Section B, Beam Interactions with Materials and Atoms. 2014, 338 42-47. ISSN 0168-583X. 2014 8
Micro-radiography of biological samples with medical contrast agents J. Dammer, F. Weyda, J. Beneš, V. Sopko, I. Gelbic Článek v časopise Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment. 2013, 730(730), 149-151. ISSN 0168-9002. 2013 1
X-ray Radiography and Tomography for Monitoring the Penetration Depth of Consolidants in Opuka - the Building stone of Prague Monuments M. Slavíková, F. Krejčí, J. Žemlička, M. Pech, P. Kotlik, J. Jakůbek Článek v časopise Journal of Cultural Heritage. 2012, 13(4), 357-364. ISSN 1296-2074. 2012 38
MICRO-RADIOGRAPHY OF LIVING BIOLOGICAL ORGANISMS WITH MEDIPIX2 DETECTOR AND APPLICATION OF VARIOUS CONTRAST AGENTS J. Dammer, V. Sopko, J. Jakůbek, F. Weyda, J. Benes Příspěvek ve sborníku In: Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications. Singapore: World Scientific, 2012. pp. 553-559. ISBN 978-981-4405-06-5. 2012 1
Combination of modern visualization techniques for imaging of biological samples F. Weyda, J. Dammer Příspěvek ve sborníku In: "Astroparticle, Particle, Space Physics and Detectors for Physics Applications", Proceedings of the 13th ICATPP Conference, Villa Olmo, Como, Italy, 3-7 October 2011. Singapore: World Scientific Publishing, Ltd., 2012. pp. 717-723. Astroparticle, Particle, Space Physics, Radiation Interaction, Detectors and Medical Physics Applications. ISBN 978-981-4405-06-5. 2012 0
Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging F. Krejčí, J. Jakůbek, M. Kroupa Článek v časopise Journal of Instrumentation. 2011, 6(C01073), 1-10. ISSN 1748-0221. 2011 18
High contrast laminography using iterative algorithms M. Kroupa, J. Jakůbek Článek v časopise Journal of Instrumentation. 2011, 6(C01045), 1-6. ISSN 1748-0221. 2011 2
X-ray Phase Contrast Imaging Using Single Absorption Coded Aperture F. Krejčí, J. Jakůbek, M. Kroupa Článek v časopise Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment. 2011, 633(1), 181-184. ISSN 0168-9002. 2011 8
The use of contrast agent for imaging biological samples J. Dammer, F. Weyda, V. Sopko, J. Jakůbek Článek v časopise Journal of Instrumentation. 2011, 1(C01096), 1-6. ISSN 1748-0221. 2011 4